Dear Alan,
These feature is present since AMBER 16 or so (at leat that is the oldest version I've tied)...
I don't think it is a bug, but Dave should certainly know better that me...
I think it is some kind of safe-lock to prevent users from doing potentially wrong things... such as over-witting force fields...
Indeed, oldff/leaprc.ff99SB and oldff/leaprc.ff99bsc0 load almost the same stuff, but for the bsc0 parameters of DNA.
Hence the right way to load the force field is just "source oldff/leaprc.ff99bsc0"
Anyway, as David mention, both the parameters and the way to load them are very old fashion...
One proper way to do it at present is:
source leaprc.protein.ff14SB
source leaprc.water.tip3p
source leaprc.DNA.bsc1
Best,
MatÃas
PS: I'm stating to use "leaprc.water.opc" and OP3 (OPC3) water model, which is much better than TIP3P for the same price :-P
----- Mensaje original -----
De: "David A Case" <david.case.rutgers.edu>
Para: "AMBER Mailing List" <amber.ambermd.org>
Enviados: Lunes, 8 de Febrero 2021 11:50:07
Asunto: Re: [AMBER] multi source calls in tleap
On Sun, Feb 07, 2021, Alan wrote:
>I've only noticed that now in ambertools 2020, perhaps that happened years
>ago, but my tleap scripts used to have:
>
>source oldff/leaprc.ff99SB
>...
>source oldff/leaprc.ff99bsc0
>Which now throws an error.
Looks like a bug to me. I've submitted a fix for the upcoming AmberTools21.
Thanks for the report.
Is there a command to "unload" or "unsource" loaded parameters?
No.
>For now I've just broken my one script in several scripts, which is fine
>but, still, it would be nice to know more about it.
Just hoping here that you have a good reason to be using such outdated force
fields.
...dac
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Thu Feb 11 2021 - 06:00:07 PST