Re: [AMBER] restraint 10 kcal/mol

From: Daniel Roe <daniel.r.roe.gmail.com>
Date: Wed, 24 Jun 2020 16:42:12 -0400

One thing to check is if you have imaging artifacts between runs. You
are using iwrap=1 so imaging is on, but restraints do not follow the
minimum image convention, so if your ligand was imaged but your
receptor wasn't that could cause an issue. If that is indeed the
problem, the solutions are to either 1) turn off wrapping (should be
fine if you're using the default netcdf restart/trajectory files) or
2) make sure you 'autoimage' (or somehow otherwise reimage) your
restart files before you use them as input coordinates.

-Dan

On Wed, Jun 24, 2020 at 2:36 PM Debarati DasGupta
<debarati_dasgupta.hotmail.com> wrote:
>
> Hi All
> I am a bit confused with regard to the NVT production runs of TI setup I had established a few weeks back.
> My ligand of interest is ethanol and my prod.in file looks like this:
> [SITE1]$ cat ./0.11505/prod_NVT.in
> &cntrl
> imin = 0, nstlim = 20000000, dt = 0.001,
> irest = 1, ntx = 5, ig = -1,
> tempi = 300.0, temp0 = 300.0,
> ntwx = 10000, ntwe = 10000, ntwr = 10000, ntpr = 10000,ntwv=-1, ntave =1000,
> cut = 11.0,
> ntt =3, ntb = 1, ntp = 0, gamma_ln=3, iwrap = 1,
> ntc = 1, ntf = 1, tol = 0.00001,
> nsnb = 10, nscm = 10,
> ioutfm=1,
> taup = 2,
> ntr=1, restraintmask=':EOH', restraint_wt=10.00,
> icfe = 1, clambda = 0.11505, ifsc=1,
> timask1=':EOH',timask2='',
> scmask1=':EOH', scmask2=''
> &end
> &ewald
> skinnb=2, nfft1=96, nfft2=96, nfft3=96,
> /
>
> So, after the run was complete, I was curious to see how far my ligand has translated from its tether point.. and after doing a COM distance cpptraj script run, I find that for 3 lambda values 0.11505, 0.20634, and 0.31608; the ligand has moved around quite a bit as in > 3 Angstroms from its initial solvated state. Is this expected or am I doing something wrong in putting the restraint weight and mask?
> I thought that 10 kcal/mol is quite a big force to keep ligand restrained in the pocket. I was not expecting a 3-4 Angstrom jiggling of the ligand atoms.
> Should I be worried?
> [cid:image001.png.01D64A34.03736FA0]
>
> Sent from Mail<https://go.microsoft.com/fwlink/?LinkId=550986> for Windows 10
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber

_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Jun 24 2020 - 14:00:03 PDT
Custom Search