Re: [AMBER] bond connections

From: Brian Radak <brian.radak.accts.gmail.com>
Date: Thu, 3 Dec 2015 12:16:56 -0600

I can't speak directly to the VMD internals, but my experience has led
me to believe that VMD will skip the heuristic distance check if a
topology file (e.g. PSF or prmtop) is read. This seemed most apparent to
me by looking at rigid waters or disulfide linkages with and w/o loading
a PDB with a matching PSF.

Brian

On 12/03/2015 12:05 PM, Jason Swails wrote:
> On Thu, Dec 3, 2015 at 12:55 PM, mohammad r <mohammad.r0325.yahoo.com>
> wrote:
>
>> When I open the amber topology file in vmd, it can read the number of
>> atoms but the number of frames is zero so it shows nothing, in opening the
>> .crd file the number of frames and atoms are zero. But when I open the .gro
>> file it shows the system correctly.
>>
> ​You need to load both the prmtop *and* the coordinate file. The prmtop
> defines the molecule, and the crd file provides the frame.
>
> Make sure you load the coordinate file as the correct type. If it is the
> inpcrd file, you need to select "Amber 7 restart", not "Amber coordinates".
>
> As for the GRO file showing the system correctly -- I believe this is
> because VMD draws the bonds based on distance, NOT necessarily what is
> inside the Gromacs or Amber topology files. You really need to check the
> appearance of the Amber topology file with Amber coordinates to see if some
> mistake was made there.
>
> HTH,
> Jason
>

-- 
Brian Radak
Postdoctoral Scholar
Gordon Center for Integrative Science, W323A
Department of Biochemistry & Molecular Biology
University of Chicago
929 E. 57th St.
Chicago, IL 60637-1454
Tel: 773/834-2812
email: radak.uchicago.edu
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Thu Dec 03 2015 - 10:30:04 PST