Hi Marcos,
Terms in this hydrogen bond correction depend on the geometry and connectivity of donor/acceptor groups. Your simulation encountered a geometry in which the computed connectivity (depends on the QM extracted bond order) is lower or higher than has been parameterized. Maybe try doing a classical geometry optimization first to make sure you have a reasonable starting geometry. Or a QM/MM geometry optimization with hydrogen bond correction. Note that it is possible to encounter this problem later on during MD.
All the best,
Andy
--
Dr. Andreas W. Goetz
Assistant Project Scientist
San Diego Supercomputer Center
Tel : +1-858-822-4771
Email: agoetz.sdsc.edu
Web : www.awgoetz.de
On Dec 10, 2014, at 9:05 AM, Marcos Serrou do Amaral wrote:
> Hi guys,
>
> I am trying to use PM6-DH+ (in AMBER12) for a QM/MM simulation.
> I have two similar systems. In the first one, the solvent is methanol and
> the simulation works fine!
>
> In another one, the solvent is ethanol and I have received the follow
> message in the first step for minimization:
>
> "SANDER BOMB in subroutine calc_h_corr2 (dh_correction_module)
> Unusual bond definitions for H-bond correction.
> Bye bye."
>
> and the simulation stops.
>
> The solutes are very similar.
> Something like this:
> solute1 = solute + CH3 and solute2 = solute + CH2 + CH3
>
>
> Do you know where could be the problem ?
>
> Cheers
> ---
> Marcos