Hi Abdul,
1 M calcium chloride will like be difficult to converge, if it converges at all. Section 7.3.1 (Amber 20) does contain all of the advice I have. The only thing I can suggest is to start with the KH closure and progressively adjust the parameters of the liquid, making sure that the old `.sav` file is used as the starting guess (this is automatic if the .`sav` file is in the same directory). I would try 1) slowly increasing the concentration of the ions and 2) set the ion charges to 0 and slowly increase them. If you can get this to work with KH, then you can try using that as a guess for higher order closures, though this becomes increasingly difficult.
Also, make sure that you decrease the concentration/density of the water in accord with the amount of salt you are adding.
Hope this helps,
Tyler
Sent with ProtonMail Secure Email.
‐‐‐‐‐‐‐ Original Message ‐‐‐‐‐‐‐
On Tuesday, January 4th, 2022 at 6:34 AM, ABDUL BASIT <abdul48_sit.jnu.ac.in> wrote:
> Dear AMBER community,
>
> I am running a 1D-RISM calculation with 1M calcium chloride with changed
>
> water density. The calculation could not converge with SPC/E and TIP3P
>
> water models though I changed input parameters as mentioned in section
>
> 7.4.1 of the Amber 20 manual.
>
> I want to know what else we can do to converge the calculation?
>
> Sincerely
>
> Abdul Basit
>
> Research Fellow
>
> School of Computational & Integrative Sciences
>
> Jawaharlal Nehru University, New Delhi-110067
>
> India
>
> AMBER mailing list
>
> AMBER.ambermd.org
>
> http://lists.ambermd.org/mailman/listinfo/amber
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Jan 04 2022 - 12:30:02 PST