On Tue, Sep 08, 2020, Dave Cerutti wrote:
>Yes, this looks like an imaging problem--if you have iwrap = 1 in your
>&cntrl, the homoDIMERIC protein is two molecules, so each will be re-imaged
>separately.
Everyone wants to chime in on this one!
It would be good to know if you are indeed using iwrap=1. If so, you
see a reaoson to avoid that in the future.
You *should* be able to undo the wrapping in cpptraj, and get a proper
RMS vs. time plot, without having to re-run any of the simulation.
Check out the "unwrap" option in cpptraj.
[This all assumes that this is indeed a wrapping problem -- as Carlos
suggests, visualization is your friend here.]
....dac