Re: [AMBER] Assigning protonation states manually to the amino vs CpH MD simulation

From: Carlos Simmerling <carlos.simmerling.gmail.com>
Date: Mon, 18 Mar 2019 10:05:15 -0400

They will if your protonation states are known and not likely to change for
the states sampled during md.

I would be surprised if HIP was appropriate for pH 8. Maybe, but not
without a pKa shift.

On Mon, Mar 18, 2019, 9:18 AM Bharat Manna <bharatmanna.gmail.com> wrote:

> Dear AMBER Users,
>
> If I assign the protonation states of the amino acid residues manually in
> the PDB file (e.g. at pH 8.0, HIS -> HIP, LYS -> LYS etc.) while generating
> the topology in Leap, and perform conventional MD simulation of the
> protein, will it be similar to Constant pH MD simulation? To be more
> precise, will the results obtained from the simulation be comparable to the
> behaviour of the protein at that particular pH?
>
> Thanks,
> B Manna
> PhD Scholar
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Mon Mar 18 2019 - 07:30:03 PDT