Dear Amber Developers and Users,
I am running some single point QM/MM in Sander (compiled as Amber16+AmberTools17) using Gaussian 09.
The calculations run ok, but I think something is not quite right with the extraction of the QM energy from the gaussian output file: the EXTERNESCF energy in the mdout file in kcal/mol doesn’t match the final energy (last ‘SCF Done’ line or ‘HF’ at the very end of the Gaussian file) when converted to kcal/mol using the conversion used in Amber (AU_TO_KCAL = 6.2750946943E+02).
I would think they should be the same.
Am I missing something obvious in the way the calculations are done or is there a problem with the way the gaussian output files are parsed?
Here is the output form Amber:
FINAL RESULTS
NSTEP ENERGY RMS GMAX NAME NUMBER
1 -5.0519E+05 1.3953E+01 1.1652E+02 CA 1579
BOND = 456.4977 ANGLE = 1327.2559 DIHED = 2177.6750
VDWAALS = 8267.2236 EEL = -89612.1756 HBOND = 0.0000
1-4 VDW = 625.9136 1-4 EEL = 7948.6914 RESTRAINT = 0.0000
EXTERNESCF = -436379.7510
And here is the final energy from Gaussian
SCF Done: E(RwB97XD) = -3178.95512525 A.U.
Which gives -1994824.4 kcal/mol and not -436379.7510 kcal/mol as found in EXTERNESCF.
Many thanks in advance for your help,
Eric
--
Eric Lang
Centre for Computational Chemistry
School of Chemistry - University of Bristol
Bristol BS8 1TS - United Kingdom
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Dec 04 2018 - 04:00:03 PST