[AMBER] NMR restraints not responding to 'value' flags in AMBER16 (pmemd.cuda)

From: Wesley Michael Botello-Smith <wmsmith.uci.edu>
Date: Fri, 22 Jul 2016 16:01:12 -0700

Hello all,
 I am running a simulation under AMBER16 using pmemd.cuda. I am attempting
to use NMR restraints to hold a ligand in place during equilibration, then
gradually release the restraints in preparation for production run.

To accomplish this, I am using 'nmropt=1' under the '&cntrl' list and
afterward:

 &wt type='REST', istep1=1,istep2=200000,
                  value1=1.0,value2=0.0, !ramp down restraint to 0
 &end
 &wt type='DUMPFREQ', istep1=1000,
 &end
 &wt type='END',
 &end

DISANG=step4.4_equilibration.rest
DUMPAVE=step4.4_equilibration.distout

The nmr restraint file (step4.4_equilibration.rest) reads:

 &rst
  ixpk= 0, nxpk= 0, iat=1276, 7908, r1=0.0, r2=2.0, r3=2.0, r4=4.0,
      rk2=50.0, rk3=50.0, ir6=0, ialtd=0,
 &end


Upon examination of the resulting trajectory, amber output and distout
files, I see that the distance between the two restrained atoms remains
roughly constant at about 2.8 to 3.0 Å

If, however, I set rk2=0.0 and rk3=0.0, the restrained atoms move away
rapidly from their starting postion at about 2.9 to a distance of about 4.5
over the 200ps trajectory.