Re: [AMBER] ig=-1 for multi production runs

From: David A Case <david.case.rutgers.edu>
Date: Mon, 21 Dec 2015 08:20:50 -0500

On Mon, Dec 21, 2015, Fabian gmail wrote:
>
> Maybe I have a trivial question, but I would like to know if I do run 10
> ns in say 5 x 2 ns runs, I guess I need to use ig = -1 only in the first
> one or in the equilibration stage only to get different samplings for
> let’s say 3 different such full runs (min + equil + prod) correct?

If you are using the Langevin thermostat (ntt=3), you should *always* set
ig=-1. If you are doing a restart calculation and using ntt=0 or 1, then the
value of ig becomes irrelevant.

....dac


_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber