Dear amber user
I am doing ti calculation with amber14 and pmemd. I dont know why the system gets unwrap during ti calculation while the iwrap is 1. my input is as follow:
runti
&cntrl
imin = 0, nstlim = 15000, irest = 1, ntx = 5, dt = 0.002,
ntt = 3, temp0 = 298.0, gamma_ln = 5.0,
ntc = 2, ntf = 1, ntb = 1, ntp = 0,
ioutfm = 1, iwrap = 1, ntxo = 2,
ntwe = 1000, ntwx = 1000, ntpr = 1000, ntwr = 1000,
icfe = 1, clambda = 0, idecomp=0,
timask1 = ':116,149', timask2 = ':159,160',
ifsc=1, logdvdl=1, dynlmb=0.0001, ntave=15,
scmask1 = ':116,149', scmask2 = ':159,160'
&ewald
/
best
Morteza
**********************************************************
Electronic Mail is not secure, may not be read every day, and should not be used for urgent or sensitive issues
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Thu Oct 15 2015 - 06:30:03 PDT