[AMBER] Thermodynamic integration goes wrong in lambda =0 while lambda = 1 is ok!!

From: Khabiri, Morteza <khabiri.med.umich.edu>
Date: Thu, 6 Aug 2015 14:43:17 +0000

________________________________
Dear Amber users

I am running thermodynamic integration with amber, pmemd on cpu, Amber14. I am using the following input file for running:

TI simulation
 &cntrl
   imin = 0, nstlim = 150000, irest = 1, ntx = 5, dt = 0.002,
   ntt = 3, temp0 = 298.0, gamma_ln = 5.0, ig = -1,
   ntc = 2, ntf = 1, ntb = 1,ntp = 0,
   ioutfm = 1, iwrap = 1,
   ntwe = 1000, ntwx = 1000, ntpr = 100, ntwr = 2000,


   icfe = 1, ifsc = 1, clambda = 0, scalpha = 0.5, scbeta = 12.0,
   logdvdl = 1,
   ifmbar = 1, bar_intervall = 1000, bar_l_min = 0.0, bar_l_max = 1.0,
     bar_l_incr = 0.1,
   timask1 = ':116,149', timask2 = ':159,160',
   scmask1 = ':116,149', scmask2 = ':159,160',


 &end

The output is:

| TI region 2


 NSTEP = 100 TIME(PS) = 0.200 TEMP(K) =445092.95 PRESS = 0.0
 Etot = ************** EKtot = 156924004.1488 EPtot = **************
 BOND = 51767754.8751 ANGLE = 299843.0710 DIHED = 13000.8615
 1-4 NB = ************** 1-4 EEL = -1193.9673 VDWAALS = **************
 EELEC = ************** EHBOND = 0.0000 RESTRAINT = 404917.1072
 EAMBER (non-restraint) = **************
 DV/DL = **************
 Ewald error estimate: 0.8890E+02
 ------------------------------------------------------------------------------

  Softcore part of the system: 64 atoms, TEMP(K) = 273603.75
 SC_Etot= 118913.0956 SC_EKtot= 52195.4965 SC_EPtot = 66717.5991
 SC_BOND= 58641.9133 SC_ANGLE= 6255.7856 SC_DIHED = 248.7149
 SC_14NB= 1571.4913 SC_14EEL= -51.8619 SC_VDW = 161.5745
 SC_EEL = -110.0186
 SC_RES_DIST= 2503.4585 SC_RES_ANG= 0.0000 SC_RES_TORS= 0.0000
 SC_EEL_DER= 6362.6956 SC_VDW_DER= *********** SC_DERIV = ***********
 ------------------------------------------------------------------------------


when I am using this input as "lambda=1" the system runs well. But when I switch to "lambda = 0" the system crashes with the following coordinates:


 -2.2263528 0.4948044 1.3902758 -9.8532522 -20.0000000 4.7261966
   6.1548176 20.0000000 3.7616364 4.3712168 0.3085792 -0.6998316
  11.9788399 -20.0000000 -20.0000000 -20.0000000 20.0000000 20.0000000
   3.6102063 2.5685121 -2.9439387 -2.4273888 -20.0000000 -20.0000000
  20.0000000 10.4990634 20.0000000 -0.6574321 4.3513134 -1.9494082
  15.8827264 -20.0000000 20.0000000 10.8980516 20.0000000 -20.0000000
  -0.2922468 3.1186614 -4.0249280 -9.9457371 4.3672343 -20.0000000
  12.1206371 -14.9312673 20.0000000 3.3266217 -1.5028986 1.1370716
 -20.0000000 -12.9537867 -20.0000000 20.0000000 20.0000000 16.7487781
  87.1893599 101.2862751 136.4590540 90.0000000 90.0000000 90.0000000

The system is very well minimized with "lambda=0" as follow:
minimisation

 &cntrl
   imin = 1, ntmin = 1, maxcyc = 600,ncyc =400,
   ntpr = 20, ntwe = 20,
   dx0 = 1.0D-7,
   ntb = 1,

   icfe = 1, ifsc = 1, clambda = 0, scalpha = 0.5, scbeta = 12.0,
   logdvdl = 0,
   timask1 = ':116,149', timask2 = ':159,160',
   scmask1 = ':116,149', scmask2 = ':159,160',

   !method 2:
   !scmask1 = '', scmask2 = ':163.HG=',
 /

 &ewald
 /




and the minimized system sounds without problem. I started the restart simulation from a previous run. With ntpr=1 also I have the same coordinate with "20000" from starting point in equillibration. Any idea why this happen when the lambda switch to 0?

Thanks

**********************************************************
Electronic Mail is not secure, may not be read every day, and should not be used for urgent or sensitive issues
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Thu Aug 06 2015 - 08:00:03 PDT