Thanks for the reply.
The system is fully equilibrated, the simulation is NPT. With iwrap turned
on, the voids do not fill in. I think that VMD is just not aware of the
periodicity of the truncated octahedron.
Is there a way that anyone knows of to correct this or another viewer that
will display the periodicity of such simulation cells correctly?
Thanks!
Paul
-----Original Message-----
From: Bill Ross [mailto:ross.cgl.ucsf.EDU]
Sent: Monday, June 21, 2010 2:11 PM
To: amber.ambermd.org
Subject: Re: [AMBER] periodic images of truc. octahedron in vmd
> Does anyone know, does VMD correctly display the periodic images of a
> truncated octahedral simulation cell created with leap? I see empty space
> in between the cells. This isn't right is it?
If the system is not equilibrated, one would expect to see a gap
between cells because of the way waters are placed initially.
This is why one needs constant pressure equilibration, to shrink
the box and lose vdw voids.
Bill
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Mon Jun 21 2010 - 15:00:03 PDT