Re: AMBER: antechamber test failure

From: David A. Case <case.biomaps.rutgers.edu>
Date: Wed, 15 Oct 2008 09:16:06 -0400

On Tue, Oct 14, 2008, john smith wrote:
>
> I am currently using Amber on my Intel Pentium IV with 1GB RAM with RedHat
> Linux EL4.
> I have compiled AmberaTools with gcc, and Amber serial version with intel
> fortran compiler (ifort).
> However, when i run the AmberTools test, i get many Possible FAILURE's for
> antechamber.
> The entries in TEST_FAILURES.diff are
>
> possible FAILURE: check ash.mol2.dif
>
> /opt/amber10/test/antechamber/ash
>
> 8c8
>
> < 2 CH3 2.0000 2.0900 0. c3 1 ACE -0.172000
>
> > 2 CH3 2.0000 2.0900 0. c3 1 ACE -0.172600
>

...etc

These all look like very small changes in charges (less than 0.01 electron),
which are expected differences between compilers.

The am1-bcc scheme first minimizes the geometry, then computes charges.
Slight differences in when the minimization terminates can lead to slight
differences in the final charges.

...dac

-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" (in the *body* of the email)
      to majordomo.scripps.edu
Received on Fri Oct 17 2008 - 05:07:17 PDT