Hi all!
I have a problem with testing basic Amber10 distribution.
After successful Amber Tools installation I`ve installed serial version of
Amber10 (with prior bugfix.all source files patching).
My OS is Suse Linux 9.3 and CPU is Pentium 4 3.20GHz.
While testing Amber10 distribution ("make test") I have similar problem with
"Targeted MD with changing target and restraints" test and "ncsu.serial"
test.
Sander works too long and doesn't finish. It seems like this:
.......................................................
.......................................................
==============================================================
cd tgtmd/change_target.rms && ./Run.tgtmd
SANDER: Targeted MD with changing target and fit/rmsd
        to different regions
diffing tgtmd.out.save with tgtmd.out
PASSED
==============================================================
cd tgtmd/change_target.ntr && ./Run.tgtmd
SANDER: Targeted MD with changing target and restraints

#No error messages, but sander cannot finish..

and like this:
..............................................................
..............................................................
==============================================================
cd amoeba_formbox && ./Run.amoeba_formbox
diffing amoeba_formbox.mdout.save with amoeba_formbox.mdout
PASSED
==============================================================
cd ncsu && ./run-serial.sh
>>>>>>> doing 'abmd_ANALYSIS'

#No error messages, but sander cannot finish..
/test/tgtmd/change_target.ntr/tgtmd.out contains only header and
/test/ncsu/abmd_ANALYSIS/mdout contains only input info.

I`ve comment out lines corresponding to these problem tests in Makefile and
after that
testing was successfully passed.

I`m not going to run Targeted MD and to use ncsu functionality (I suppose
it`s related to Adaptively
biased MD, steered MD, and umbrella sampling with REMD) in my work.
But could these testing problems be sufficient to suppose something wrong
in basic Amber functioning?