Re: AMBER: Mg2+ issues of using MM-PB/GBSA

From: mingche Pan <panmingche.yahoo.com>
Date: Fri, 2 Dec 2005 10:09:28 -0800 (PST)

Were these differences observed with the same radii for Mg2+ and everything else, i.e. using the radii in the same prmtop file (for pbsa, this means using the radiopt=0)?

  --------------------------------------
   
  Sorry! I forgot to mention that for PB calculation, I used readiopt = 1, not 0. For each radius, I changed Both Born radii of Mg2+ in prmpot file and corresponding Mg2+ radius in the mdread.f file (for sander and pbsa). Did I do something wrong?
   
  Mingche

                
---------------------------------
 Yahoo! Personals
 Single? There's someone we'd like you to meet.
 Lots of someones, actually. Try Yahoo! Personals
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Fri Dec 02 2005 - 18:53:00 PST