On Fri, Apr 02, 2004, Carsten Detering wrote:
>
> I am running a simple gas-phase minimization, using this input
>
> Minimization of dUMP i the gas-phase
> &cntrl
> imin=1, maxcyc=1000, ntmin=1, ncyc=500, ntpr=10
> &end
To run a "gas-phase" simulation you really want a non-periodic calculation.
That is, you should set up your system without a periodic "box", then set
ntb=0 in the input file, along with a large cutoff, say cut=99.
You can see an example of this sort of calculation in the $AMBERHOME/test/dmp
directory.
....good luck..dac
--
==================================================================