ARES PRIVATE
My email address is now .a-star.edu.sg. Kindly update your address book accordingly.
Hi Zhen,
Thanks for the clarification.
I am curious if IOD parameters instead of CM are better for structural refinements of modeled RNAs? It is mentioned in the manual, but I could not find any citation in the context of nucleic acids.
Thanks,
Mandar
From: Li, Zhen <lizhen6.chemistry.msu.edu>
Date: Thursday, 8 January 2026 at 12:27 AM
To: amber.ambermd.org <amber.ambermd.org>, Mandar Kulkarni <mandar_kulkarni.a-star.edu.sg>
Subject: Re: [AMBER] Mg2+ parameters: Optimized or CM
CAUTION:
External email. Exercise caution with links and attachments.
Hi Mandar,
Thank you for being interested in using the Li-Merz Parameters for Mg2+.
To clarify, the Rmin/2 and epsilon parameters in Ref. 145 are not designed for 12-6 only. They must be used with the 12-6-4 model, as outlined in this tutorial<
https://ambermd.org/tutorials/advanced/tutorial20/12_6_4.php>. The intended C4 values are listed in Table 4 of Ref. 145.
If the parameter is used with the Joung-Cheatham Cl- parameter, then the Mg2+ CM set (from Ref. 144) should perform well. Hope it is clear.
Best regards,
Zhen.
_____________________
Zhen Li<
http://lizhen62017.wixsite.com/home>, Ph.D.,
The Merz Research Group<
http://merzgroup.org>,
Michigan State University,
Cleveland Clinic.
________________________________
From: Mandar Kulkarni via AMBER <amber.ambermd.org>
Sent: Wednesday, January 7, 2026 7:00 AM
To: amber.ambermd.org <amber.ambermd.org>
Subject: [AMBER] Mg2+ parameters: Optimized or CM
ARES PRIVATE
My email address is now @a-star.edu.sg. Kindly update your address book accordingly.
Dear AMBER developers,
I am reading the AMBER25 manual for ion parameter suggestions and noticed that Mg2+ CM parameters with TIP3P are cited from Ref. 145 (J. Chem. Theory Comput., 2014, 10, 289–297), and found them mentioned in Ref. 144 also (J. Chem. Theory Comput., 2013, 9, 2733–2748) .
Ref. 145 mentions different set of optimized parameters for Mg2+ (Rmin/2 = 1.437 and epsilon = 0.02257962), whereas CM parameters are (Rmin/2 = 1.360 and epsilon = 0.01020237).
Can developers confirm which set is correct for RNA simulations in TIP3P and Joung-Cheatham Cl- ions?
Also, is the IOD set from Ref. 144 better for equilibrating predicted RNA models?
Thanks,
Mandar
This e-mail and any attachments are only for the use of the intended recipient and may contain material that is confidential, privileged and/or protected by the Official Secrets Act. If you are not the intended recipient, please delete it or notify the sender immediately. Please do not copy or use it for any purpose or disclose the contents to any other person.
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
https://urldefense.com/v3/__http://lists.ambermd.org/mailman/listinfo/amber__;!!HXCxUKc!zcgIUL5aABPKXjnrt3ROAtKi9hBgF5TIV4-RIFHgg2lVUM3dMFZmYyomCpEm9LGwL0r2mW1jBSeEpWNKoLkur2U$
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Jan 07 2026 - 09:30:03 PST