Re: [AMBER] Holding Host-Guest COM constant during binding enthalpy MD

From: Gert Kruger via AMBER <amber.ambermd.org>
Date: Wed, 8 Nov 2023 05:44:15 +0000

Dear Olivia,

Are you using QM for the guest molecule and the atoms in the active site where it is binding?

I would imagine this will improve the binding interactions.

Can you share with us the host guest system you are using (even just a general description)?

If the host leaves the binding site, it is possible due to the chemical forces being weak. Seeing the system will help us to tell you if one expects good or weak binding.

Best wishes
Gert Kruger

On Tue, 2023-11-07 at 19:00 +0000, Meyer, Olivia (meyerok) via AMBER wrote:
Good Afternoon,

I have a general question regarding a host-guest system I am investigating. I am attempting to determine binding enthalpy using the method provided in the Computing Binding Enthalpies Tutorial, involving CB7 and B2 as the respective host and guest. Although the general process of the tutorial is understandable, when I replicate this technique using a different host/guest system my guest and host are not staying bound (the earliest evidence of this is the NVT simulation, prior to any NPT simulations). The guest is leaving the host cavity, but I cannot calculate a binding energy if they are not bound. I have attempted to resolve this issue using multiple strategies, which I have listed below, where none of these strategies have provided the desired effect I am attempting to replicate.

1. Providing -ref coordinate files (this was just a guestimate-type solution)
2. Restraining the host and guest using 'RES 1 2' command with a restraining force of 100.0 (I have done this with ntc=2, ntf=2, ntr=0 (scenario a—which does not keep the host-guest complex bound together), ntc=2, ntf=2, ntr=1 (scenario b—completely constrains their positions and does not allow any movement whatsoever)

I am somewhat at a loss now, as I do not have anymore experience to move forward in an educated way, other than trying another method (potentially using the attach-pull-release method of the other binding enthalpy tutorial). If anyone has suggestions, I would be sincerely grateful.

-Olivia

Olivia K. Meyer
Graduate Student, Kumari Lab
University of Cincinnati
James L. Winkle College of Pharmacy
Department of Pharmaceutical Sciences
231 Albert Sabin Way, Cincinnati, OH USA 45229



_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber<https://protect-za.mimecast.com/s/ADVzC1j735f73ZoKfG6YKE?domain=lists.ambermd.org>


UKZN email disclaimer:
The contents of this e-mail may contain personal information, and/or privileged information, and/or confidential information. The information contained herein is therefore only meant for consumption by the recipient mentioned and for the purpose as specified in the body of the e-mail. Should you receive this e-mail in error kindly inform the sender of such by responding to the sender via a response e-mail and thereafter please delete the original e-mail received as well as the response e-mail. The University of KwaZulu-Natal e-mail platform is meant for business purposes (of the University) only and the University therefore does not accept any liability whatsoever that may arise from instances where such platform is utilised for personal reasons. Any views or opinions expressed in this e-mail represent those of the author and may not necessarily be binding on the University. The author of the e-mail may also not bind the University in any manner that may be construed from the contents of the e-mail unless such sender has been granted the requisite authority to do so by the University.
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Nov 07 2023 - 22:00:02 PST