[AMBER] ParmEd problem: LJ12_6_4 +pTYR. Error: Could not find parameters for ATOM_TYPE CG

From: Paiardi, Giulia via AMBER <amber.ambermd.org>
Date: Fri, 17 Mar 2023 11:56:09 +0000

To whom it may concern,


I'm parametrizing a protein containing Zn2+ ions and pTYR (pTyr is parametrized in ff19SB as PTR) using amber22 with ff19SB and OPC water model.?


When I add the 12-6-4 Lennard-Jonnes potential for Zn2+ to the protein with canonical tyrosine parmed works OK.


If I substitute the canonical TYR with PTR (phosphorylated tyr), I can still obtain the parameters and the restart file,

however, when adding the 12-6-4 Lennard-Jonnes potential for Zn2+ to the parameter file of the complex, parmed gives to me the following error:


#################


Loaded Amber topology file com.wat.leap.prm7

['parmedOPC.1264.in']

Reading actions from parmedOPC.1264.in


Loading restart file com.wat.leap.rst7

Files are overwritable

Adding Lennard-Jones C-coefficient for 12-6-4 potential. Polarizabilities read from [/hits/fast/mcm/app/amber/cascade/amber22/dat/leap/parm/lj_1264_pol.dat]. Using default C4 parameters for water model [OPC].

***********************************************************

The selected metal ion is Zn

Action add12_6_4 failed

LJ12_6_4Error: Could not find parameters for ATOM_TYPE CG


##################


What should I do? Any advise is a great help to me.

?

Thanks for the help,

Giulia