[AMBER] OPC3-pol

From: Piia Bartos via AMBER <amber.ambermd.org>
Date: Mon, 21 Nov 2022 11:20:53 +0000

Hi Amber people,

I tried to test the new OPC3-pol water model with my protein system.

It seems to be incompatible with some of my simulation parameter, as the simulations with the OPC3-pol water appear to be "frozen", where atoms remain almost still thorough the simulation (500 ns). The same production script works fine for OPC water model. Any ideas what I need to change? The issue might be with the Parmed, HMR and using 4fs timestep, but I think I built the system correctly...

Here is the production script:
# 500 ns production Langevin thermostat + Monte carlo barostat dynamics
 &cntrl
   imin=0,
   irest=1, ntx=5,
   ntpr=25000, ntwx=25000, ntwr=25000,
   ntb=2, barostat=2, cut=10, iwrap=1,

   nstlim=125000000, nscm=0, dt=0.004,
   ntt=3, gamma_ln = 1, ig=-1, temp0=310, tempi=310,
   ntp=1,
   ntc=2, ntf=2,
   ioutfm=1,
  /
&ewald
   netfrc = 0,
   skin_permit = 0.75,
&end
/

Cheers,
Piia

--