Re: [AMBER] Imaging issue in DNA - cpptraj

From: Gustaf Olsson <gustaf.olsson.lnu.se>
Date: Wed, 2 Dec 2020 08:12:38 +0000

Short of increasing the solvent buffer to avoid jumps, trying to play around with the masks for image/autoimage seems reasonable.

See what happens if you autoimage with a mask defined. Either trying to center the entire DNA or as suggested (https://amberhub.chpc.utah.edu/autoimage/), try imaging using a small region of the DNA which should be close to the center of the box.

Best regards
// Gustaf


On 2 Dec 2020, at 08:17, Satyaseelan C <bo17resch11006.iith.ac.in<mailto:bo17resch11006.iith.ac.in>> wrote:

Dear Amber users,
              I am facing an imaging issue during the MD simulation of a
DNA duplex. Due to this, the RMSD is shooting up and falls back during the
middle of the simulation. I am observing this problem for 50ns during the
simulation. I used autoimage option followed by image option as below:

parm prmtop
trajin trajin.nc
autoimage
center :1-16 origin
image origin center familiar
center :1-32 origin
image origin center familiar
trajout reimage.nc
go

When I don't apply any imaging, the DNA strands are separated and going out
of the box in some frames. But, after performing imaging, the problem is
not completely resolved. Here, a stretch of DNA strand is going away and
causes distortions in the structure for 50ns. I have attached the
corresponding snapshots.

Please suggest any alternative options to overcome this issue.


Thanks in advance
Sathyaseelan

--
*Thanks & Regards*
*C .Sathyaseelan *
*PhD Research Scholar*
*C/o Dr. Thenmalarchelvi Rathinavelan*
*Molecular Biophysics Lab*
*Dept. of Biotechnology*
*Indian Institute of Technology (IIT)*
*Kandi, Hyderabad, Telangana - 502285*
*Ph.No 6383836804, 8300150807*
--
Disclaimer:- The information contained in this electronic message and any
attachments to this message are intended for the exclusive use of the
addressee(s) and may contain proprietary, confidential or privileged
information. If you are not the intended recipient, you should not
disseminate, distribute or copy this email. Please notify the sender
immediately and destroy all copies of this message and any attachments. The
views expressed in this E-mail message (including the enclosure/(s) or
attachment/(s) if any) are those of the individual sender, except where the
sender expressly, and with authority, states them to be the views of IIT
Hyderabad. Before opening any mail and attachments please check them for
viruses, malware, and the sender email address is indeed from IITH domain.
IITH does not accept any liability for malware infected mails.
<nowaterbox.png><waterbox.png>_______________________________________________
AMBER mailing list
AMBER.ambermd.org<mailto:AMBER.ambermd.org>
http://lists.ambermd.org/mailman/listinfo/amber
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Dec 02 2020 - 00:30:02 PST
Custom Search