[AMBER] FW: AMBER20 TI calculations

From: Debarati DasGupta <debarati_dasgupta.hotmail.com>
Date: Fri, 27 Nov 2020 17:52:37 +0000

Sent from Mail<https://go.microsoft.com/fwlink/?LinkId=550986> for Windows 10

From: Debarati DasGupta<mailto:debarati_dasgupta.hotmail.com>
Sent: 27 November 2020 12:37
To: Adrian Roitberg<mailto:roitberg.ufl.edu>
Subject: RE: [AMBER] AMBER20 TI calculations

Hello Prof Roitberg,
Thanks for your reply, really appreciate it.
SO this is the input file (for clambda=0.20634) which leads me to the unstable simulation:
&cntrl
    imin = 0, nstlim = 100000, dt = 0.001,
    irest = 0, ntx = 1, ig = -1,
    tempi = 0.0, temp0 = 50.0
    ntc = 1, ntf = 1, tol = 0.00001,
    nsnb = 10, nscm = 10,
    ioutfm=1,
    taup = 1,
    ntwx = 100, ntwe = 100, ntwr = 100, ntpr = 100, ntwv=-1, ntave = 100,
    cut = 11.0, iwrap = 1,
    ntt =3, ntb = 1, ntp = 0, gamma_ln=1.0,
    nscm = 0,
    icfe = 1, clambda=0.20634, ifsc=1,
    timask1=':IPA',timask2= '', scalpha = 0.1, scbeta = 50.0,
    scmask1 = ':IPA', scmask2 = '',
nmropt=1,
/
&wt type='DUMPFREQ', istep1=1, /
&wt type='END', /
DISANG=output.disang
DUMPAVE=dist_0.20634.dat
LISTIN=POUT
LISTOUT=POUT
/
&ewald
   skinnb=2, nfft1=96, nfft2=96, nfft3=96,
/
&wt type='TEMP0', istep1=0, istep2=90000, value1=0.0, value2=50.0 /
&wt type='TEMP0', istep1=90001, istep2=100000, value1=50.0, value2=50.0 /
&wt type='END' /

Also, when I use harmonic restraints (ntr=1), the simulation does not crash.
I am running a 10 step heating without restraints to check on the run.
Do you want me to provide you the prmtop and inpcrd file?
Thanks
Debarati








From: Adrian Roitberg<mailto:roitberg.ufl.edu>
Sent: 27 November 2020 12:21
To: AMBER Mailing List<mailto:amber.ambermd.org>; Debarati DasGupta<mailto:debarati_dasgupta.hotmail.com>
Subject: Re: [AMBER] AMBER20 TI calculations


Hard to tell without more details, but...

You are getting warning about NMR restraints, I would check those first.

What happens if you take the restraints out just to check on the run ?



Your box size seems to be immense. I very much doubt that your system is 91 MICROMETERS to the side !

adrian


On 11/27/20 12:15 PM, Debarati DasGupta wrote:

[External Email]



Hello everyone,

I am running an absolute binding free energy calculation on a ABL kinase system ( ligand is isopropanol), I have applied distance based restraints to keep the ligand in the pocket:

However, after minimization, the system gets unstable in the temperature ramping simulation I get this: ( see picture below). Any ideas/thoughts on how to prevent this?

I have used softcore potentials and I am doing a stepwise de-charge, then disappearing the LJ interactions.

Thanks

Debarati

[cid:image001.png.01D6C4B6.D8F0CCC0]




_______________________________________________

AMBER mailing list

AMBER.ambermd.org<mailto:AMBER.ambermd.org>

https://urldefense.proofpoint.com/v2/url?u=http-3A__lists.ambermd.org_mailman_listinfo_amber&d=DwICAg&c=sJ6xIWYx-zLMB3EPkvcnVg&r=dl7Zd5Rzbdvo14I2ndQf4w&m=Nz66HmI3RSWX1YYqpIibquP5uwmJXSaJfyBXz2Dj2Og&s=3LaEPA3Mr3v3ADH4oHWYh4gtj3mp-7hLAH2ThxtrRyw&e=

--
Dr. Adrian E. Roitberg
V.T. and Louise Jackson Professor in Chemistry
Department of Chemistry
University of Florida
roitberg.ufl.edu<mailto:roitberg.ufl.edu>
352-392-6972
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Fri Nov 27 2020 - 10:00:02 PST