Re: [AMBER] System blows up when simulating under npt

From: Carlos Simmerling <carlos.simmerling.gmail.com>
Date: Tue, 24 Nov 2020 06:09:42 -0500

Have you tried the simulation without adding the adduct? Also you didn't
describe your equilibration protocol. I believe the one we used should be
described in our paper on that system. Dan Roe also has a nice paper on
equilibration.
Carlos

On Tue, Nov 24, 2020, 6:05 AM Amit Sharma (Asstt. Prof., MCARS) <
asharma4.jmi.ac.in> wrote:

> Hi,
>
> I trying to simulate protein having of FMN Cys adduct.
>
> When running md using nvt and positional restraints of 0.5 kcal mol-1 A-2
> on the protein, the system remains fine.
>
> But as I switch to npt and remove all the restraints system blows up and
> water molecules start flying away.
>
> Error message is as follows:
>
> "ERROR: Calculation halted. Periodic box dimensions have changed too much
> from their initial values.
> Your system density has likely changed by a large amount, probably from
> starting the simulation from a structure a long way from equilibrium.
>
> [Although this error can also occur if the simulation has blown up for
> some reason]
>
> The GPU code does not automatically reorganize grid cells and thus you
> will need to restart the calculation from the previous restart file.
> This will generate new grid cells and allow the calculation to continue.
> It may be necessary to repeat this restarting multiple times if your
> system
> is a long way from an equilibrated density.
>
> Alternatively you can run with the CPU code until the density has
> converged
> and then switch back to the GPU code."
>
> Can anyone suggest how to deal with this?
>
> Thank You,
>
> Amit
>
> --
> _
> _
>
>
>
> *Please consider the environment before printing this email.*
> The
> information contained in this electronic message and any *attachments to
> this message are intended for the exclusive use of addressee(s) and may
> contain proprietary, confidential or privileged information. If you are
> not
> the intended recipient, you should not disseminate, distribute **or copy
> this e-mail. Please notify the
> sender immediately and destroy all copies of
> this message and any attachments.***
> **
> **WARNING***: The recipient should
> check this email and any attachments for
> the presence of viruses. JMI
> accepts no liability for any damage caused by any
> virus transmitted by this
> email.*
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Nov 24 2020 - 03:30:02 PST