Re: [AMBER] TI not compatible with GB on GPU

From: Debarati DasGupta <debarati_dasgupta.hotmail.com>
Date: Wed, 21 Oct 2020 12:21:46 +0000

Hi Vaibhav,
Welcome to the TI club!
I feel on GPUs, you should be using pmemd.MPI not pmemd.cuda as I have used pmemd.MPI while running my TI jobs.
Also I am not sure what is the exact system your studying as 100-150 kcal/mol looks like a very very high energy binding process.
I have some weak binders I work on and my free energies are in the range of -1 to -3 kcal/mol for binding to my kinase.
Also the Amber20 TI-GPU is pretty fast. On a single GPU, I get about ~70ns/day in equilibration stages.
I am not sure if we could use implicit solvents for TI, I have been using TIP3P water.
Thanks
I hope I could help somewhat.
Debarati

Sent from Mail<https://go.microsoft.com/fwlink/?LinkId=550986> for Windows 10

From: Vaibhav Dixit<mailto:vaibhavadixit.gmail.com>
Sent: 20 October 2020 09:02
To: AMBER Mailing List<mailto:amber.ambermd.org>
Subject: [AMBER] TI not compatible with GB on GPU

Dear Amber users/experts,
I'm running at TI calculation on CPU but it is expected to take 353 hr to
complete.
When I tried to run the same on GPU with pmemd.cuda I'm getting hte subject
error mentioned below.
Can someone on the list please guide me if there is a way around this or is
it not possible with Amber18 on GPU?
Additionally, I was expecting free energy values in the range 100-115
kcal/mol, but I'm getting 180 kcal/mol values. I did run a 30 ns
simulation on the model compound but values did not change much. I used
procedure similar to that given in the tutorial here
<http://ambermd.org/tutorials/advanced/tutorial6/section4.php>. My system
is Heme with and without extra electron, charges were derived from MCPB.py
tool.

We are processing the purchase of Amber20, but it might take 15-20 days or
more before the payment goes through. Is this something available in
Amber20?
thank you and best regards.

Error while running GB based TI on GPU

Note: ig = -1. Setting random seed to 390103 based on wallclock time in
      microseconds.
| irandom = 1, using AMBER's internal random number generator (default).
| ERROR: TI is incompatible with GB on GPU

 Input errors occurred. Terminating execution.

--
Regards,
Dr. Vaibhav A. Dixit,
Visiting Scientist at the Manchester Institute of Biotechnology (MIB), The
University of Manchester, 131 Princess Street, Manchester M1 7DN, UK.
AND
Assistant Professor,
Department of Pharmacy,
ŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒŒ
Birla Institute of Technology and Sciences Pilani (BITS-Pilani),
VidyaVihar Campus, street number 41, Pilani, Rajasthan 333031.
India.
Phone No. +91 1596 255652, Mob. No. +91-7709129400,
Email: vaibhav.dixit.pilani.bits-pilani.ac.in, vaibhavadixit.gmail.com
http://www.bits-pilani.ac.in/pilani/vaibhavdixit/profile
https://www.linkedin.com/in/vaibhav-dixit-b1a07a39/
ORCID ID: https://orcid.org/0000-0003-4015-2941
http://scholar.google.co.in/citations?user=X876BKcAAAAJ&hl=en&oi=sra
P Please consider the environment before printing this e-mail
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Oct 21 2020 - 05:30:02 PDT