On Sat, Feb 29, 2020, SHAUNAK BADANI wrote:
>
>I am a beginner and I am trying to generate drug parameters for
>my system. I followed the antechamber tutorial and was able to
>generate drug.lib and drug.frcmod files (attached). When I run a short
>equilibration of the drug in vacuum, it seems to be fine but when I use
>these parameters to run a short drug+water system equilibration, the
>system seems to break apart (drug+water.png image attached). Can anyone
>help me in figuring out why this is happening?
Looks like an imaging issue: use the autoimage command in cpptraj to
pack everything back into a primary unit cell, then see if things look
better. (Note that imaging or lack of imaging has no effect on the
actual simulation; it only affects visualization.)
...good luck...dac