[AMBER] antechamber QM calculation/qmcharge error

From: Rui Chen <rchen6.ualberta.ca>
Date: Wed, 20 Nov 2019 22:25:53 -0700

Hello,

I am using antechamber to prepare a ligand according the following
tutorial: https://ambermd.org/tutorials/basic/tutorial4b/index.html

I got the following error: Errors in antechamber: QM CALCULATION INFO

--------------------------------------------------------------------------------

QMMM: System specified with odd number of electrons ( 141)

QMMM: but odd spin ( 1). You most likely have the charge of

QMMM: QM region (qmcharge) set incorrectly. Correct error and re-run
calculation.


Instead of using bcc charge method, I used gas charge method, the problem
was solved. My question is how to select the charge method? If there is a
specific reason to use bcc charge method, should use RED (
https://upjv.q4md-forcefieldtools.org/RED/) to solve the problem?


Looking forward to your reply.


Best regards,

Rui