Re: [AMBER] Ligand parameterization

From: Gerald Monard <Gerald.Monard.univ-lorraine.fr>
Date: Tue, 3 Sep 2019 15:17:16 +0200

Hello Hira,

There is a problem in your .mol2 file: in the BOND section, there are
two lines (10 and 11) that describe the same bond between atom 4 and
atom 5. I guess that this .mol2 file was not generated correctly. Check
your procedure and recreate this .mol2 file, that should correct your
problem.

Best,

Gerald.

On 9/3/19 12:56, Hira Jabeen wrote:
> Hi everyone,
> I am parameterizing a small ligand in Amber 18 with ambertools19.
> On saving parameters, I get the following error:
>> saveamberparm MEM MEM.prmtop MEM.inpcrd
> Checking Unit.
> Building topology.
> Building atom parameters.
> Building bond parameters.
> Building angle parameters.
> Building proper torsion parameters.
> !FATAL ERROR----------------------------------------
> !FATAL:    In file [unitio.c], line 1810
> !FATAL:    Message: 1-4: cannot add bond 4 5
> This may be caused by duplicate bond specifications;
> for example, explicit bond commands in addition to PDB conect records.
> !
> !ABORTING.
> Ligand and leap files are attached.Need your advice.
> Thanks,Hira
>
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber

-- 
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Sep 03 2019 - 06:30:02 PDT