[AMBER] system explosion

From: Hadi Rahmaninejad <ha.rahmaani.gmail.com>
Date: Thu, 7 Mar 2019 18:18:30 -0500

Hello Amber Users,

I have a silica system which I solvated it in water by "psfgen" and then
converted it to amber using "chamber" in "parmed". In coordinate file I
dont have that line at the end which shows the dimension and angles of the
box, so that I added that line by myself:
50.0000000 50.0000000 50.0000000 90.000000 90.0000000 90.0000000
the "50" that I defined is the length of my system in any direction. When I
minimized that using:
Minimize
 &cntrl
  imin=1,
  ntx=1,
  irest=0,
  jfastw=4,
  maxcyc=200,
  ncyc=100,
  ntpr=1,
  ntwx=1,
  cut=19.0,
  ntb=1,
  ntp=0,
 /
The bonds start to expand (even water bonds) and then the system exploded
after about 115 frames, and I got this error:
Program received signal SIGSEGV: Segmentation fault - invalid memory
reference.

Backtrace for this error:
#0 0x7F526F55CE08
#1 0x7F526F55BF90
#2 0x7F526EC8D4AF
#3 0x54EB9B in nb_adjust_
#4 0x5509BF in ewald_force_
#5 0x722A2D in force_
#6 0x4E897A in runmin_
#7 0x4D46A3 in sander_
#8 0x4CBF39 in MAIN__ at multisander.F90:?
Segmentation fault

Do anybody have such experience? I highly appreciate if you can help me,

Best Regards,
Hadi
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Thu Mar 07 2019 - 15:30:01 PST