Re: [AMBER] Regarding the Targeted MD

From: M. Reza Ganjalikhany <ganjalikhany.gmail.com>
Date: Fri, 30 Nov 2018 12:52:00 +0330

Here are the links to the outputs:
https://www.dropbox.com/s/lkytj6a70wpr5kc/tmd5.out?dl=0
https://www.dropbox.com/s/webobxahghmchs2/tmd2.out?dl=0
https://www.dropbox.com/s/x6ni7r1vxelextr/tmd.out?dl=0


On Fri, Nov 30, 2018 at 2:08 AM Carlos Simmerling <
carlos.simmerling.gmail.com> wrote:

> Can you send me the output file off list?
> Carlos
>
> On Thu, Nov 29, 2018, 8:32 AM M. Reza Ganjalikhany <ganjalikhany.gmail.com
> wrote:
>
> > Dear Carlos,
> >
> > As my structure has a large and complicated conformational change along
> two
> > axes, I am not sure whether TMD is enable of simulating such transition
> in
> > a low energy path or just move the structure to lower the RMSD value
> > regardless of any other parameters.
> >
> > Both cases (ntr=1. restrantmask) and (ntr=0 and tgtfitmask) worked with a
> > slight difference. The output shows it recognizes the masks as reported
> > below:
> >
> > 5. REFERENCE ATOM COORDINATES
> >
> > defa
> > Mask :1-114,131-166,188-204,229-249,448-577.CA; matches 318 atoms
> > Mask ":115-130,167-187,205-228,250-447,578-775.CA" matches 437
> > atoms
> >
> > As you mentioned, I used cpptraj to see the changing in the RMSD value.
> It
> > decreased until the half and then it increased slowly as it could not
> find
> > the final position. The decrease is due to the movement of N-terminal
> > domain to the reference structure but it should rotate to fit the target.
> > It seems that the combination of these two movement is not possible at
> the
> > same time.
> > Also, I have tested bigger force constants and the result was not really
> > desirable as the structure denatured during the movement.
> >
> > Here are the links to some visualized trajectories:
> > https://www.dropbox.com/s/weezo4c1hmoc68j/TMD1.mp4?dl=0
> > https://www.dropbox.com/s/htjdlyuohlglxt5/TMD2.mp4?dl=0
> > https://www.dropbox.com/s/j7idltd4ax0iaw1/TMD5.mp4?dl=0
> >
> > On Tue, Nov 27, 2018 at 12:24 AM Carlos Simmerling <
> > carlos.simmerling.gmail.com> wrote:
> >
> > > also your force constant is really small
> > >
> > > On Mon, Nov 26, 2018 at 3:52 PM Carlos Simmerling <
> > > carlos.simmerling.gmail.com> wrote:
> > >
> > > > see section 20.4 of the Amber18 manual - you should be using
> tgtfitmask
> > > > and tgtrmsmask but I only see tgtrmsmask in your input.
> > > > I'm not sure what would happen when you also turn on positional
> > > restraints
> > > > as you have done here (using ntr=1 and restraintmask)- it might work,
> > but
> > > > it might not depending on how that matches the other masks. I don't
> > have
> > > > the ability to check the code right now.
> > > > what does the beginning of the output say about the targeted md part?
> > > does
> > > > it give a fitmask?
> > > >
> > > > to check and see if it's working, the best way is to use cpptraj to
> do
> > > the
> > > > rmsd fit to the same reference structure that you gave the md code,
> > using
> > > > the same mask as you use for tgtfitmask, and then calculate the rmsd
> > next
> > > > using the tgtrmsmask but including the "nofit" flag. The resulting
> data
> > > > stream should match what you asked the md to do (though it's unlikely
> > > that
> > > > it can reach exactly 0 rmsd).
> > > >
> > > >
> > > > On Mon, Nov 26, 2018 at 3:22 PM M. Reza Ganjalikhany <
> > > > ganjalikhany.gmail.com> wrote:
> > > >
> > > >> Dear Amber users,
> > > >>
> > > >> I am trying to run targeted MD to study a large conformational
> change
> > > >> during the simulation between two states of a protein. As I check
> the
> > > >> movies from the trajectories, I see that the structure moves from
> > > initial
> > > >> to the final structure, but it does not stop at the final point and
> it
> > > >> continues to move further beyond the final position. Also, the
> moving
> > > part
> > > >> of the structure hits other parts of the protein and I realize that
> > this
> > > >> movement will not show the low energy path between the initial and
> > final
> > > >> conformations.
> > > >> I have changed the parameters but I couldn't solve the problem.
> Since
> > I
> > > >> performed short simulations to see the results quickly, I am not
> sure
> > > >> whether I have to set large number for *nstlim *or reduce the
> *tgtfrc
> > ?
> > > >> *Is
> > > >> there any other parameter which is neglected or should be defined in
> > the
> > > >> input file? The input file has been attached. I wanted to send the
> > > movies
> > > >> but it is not possible due to the limitation is the email size.
> > > >>
> > > >> I appreciate you valuable comment to tackle this problem.
> > > >>
> > > >> Regards,
> > > >>
> > > >> Input parameters for targeted MD:
> > > >> TMD icl2
> > > >> &cntrl
> > > >> imin = 0, ntx = 1, nstlim = 12000, irest=0, dt = 0.002, ntc = 2,
> > ntf =
> > > >> 2,
> > > >> tol = 0.000001, tempi = 100.0, temp0 = 300.0, cut = 10.0,
> > > >> ntpr = 10, ntwx = 10, ntwr = 100, ntb = 0, ntt = 1, tautp = 0.5,
> > ntp =
> > > >> 0,
> > > >> igb = 1, nscm = 0, nmropt = 1, ntr = 1, restraint_wt=0.02,
> > > >> itgtmd = 1, tgtrmsd = 39.553, tgtmdfrc = 0.005, restraintmask=
> > > >> ":1-114,131-166,188-204,229-249,448-577.CA"
> > > >> tgtrmsmask= ":115-130,167-187,205-228,250-447,578-775.CA",
> > > >> /
> > > >> &wt
> > > >> TYPE='TGTRMSD', istep1=1, istep2=8000,
> > > >> value1 = 0.0500, value2 = 0.0,
> > > >> /
> > > >> &wt
> > > >> TYPE='TGTRMSD', istep1=8000, istep2=12000,
> > > >> value1 = 0.0, value2 = 0.0,
> > > >> /
> > > >> &wt
> > > >> type="END",
> > > >> _______________________________________________
> > > >> AMBER mailing list
> > > >> AMBER.ambermd.org
> > > >> http://lists.ambermd.org/mailman/listinfo/amber
> > > >>
> > > >
> > > _______________________________________________
> > > AMBER mailing list
> > > AMBER.ambermd.org
> > > http://lists.ambermd.org/mailman/listinfo/amber
> > >
> > _______________________________________________
> > AMBER mailing list
> > AMBER.ambermd.org
> > http://lists.ambermd.org/mailman/listinfo/amber
> >
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Fri Nov 30 2018 - 01:30:02 PST
Custom Search