Re: [AMBER] Coordinate messed up after tleap set box

From: Simon Kit Sang Chu <simoncks1994.gmail.com>
Date: Tue, 4 Sep 2018 11:39:48 -0700

David,

I do notice the last line of $NAMEd.inpcrd is indeed following what I set.
The only problem is when I do a simulation. The "gap" is only present after
one step simulation. I am posting the input file here as a check:

&cntrl
        imin = 0, ! no minimisation
        ntx = 1, ! restart with only coordinate ( not possible in TI
setting )
        irest = 0, ! no restart ( no initial velocity )
        nstlim = 10,! number of steps ( 0 ns )
        dt = 0.002, ! step size
        ntf = 2, ! not to calculate force for SHAKE constrained bonds
        ntc = 2, ! SHAKE for all hydrogen bonded
        temp0 = 300.0, ! temperature
        ntpr = 100, ! info frequency
        ntwx = 100, ! trajectory frequency
        ntwr = 100, ! restart frequency
        cut = 12.0, ! cutoff
        ntb = 2, ! PBC for constant pressure
        ntp = 1, ! Berendsen barostat
        ntt = 3, ! Langevin thermostat
        gamma_ln=2.0, ! Langevin thermostta frequency
        ig = -1, ! random seed
        iwrap = 1, ! PBC trajectory wrapping

        icfe = 1, ! Free energy calculation ( TI )
        clambda = 0.0 ! lambda
        klambda = 1 ! linear mixing ( required by soft-core )
        ifsc = 1, ! Use soft-core potential
        ntf = 1, ! complete hamiltonian ( required by soft-core )
        scalpha = 0.5, ! soft-core scaling ( default )
        timask1='.17,18,19,20,21,22',
        timask2='.23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38',
        scmask1='.17,18,19,20,21,22',
        scmask2='.23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38',
/

As far as I can tell, I cannot see anything problematic here. That's why I
asked if it is a problem in tleap. The gap is very visible after
simulation, a cross with gap size ~ a few angstroms.

Simon

Simon

David A Case <david.case.rutgers.edu> 於 2018年9月4日週二 上午10:37寫道:

> On Tue, Sep 04, 2018, Simon Kit Sang Chu wrote:
>
> >
> > I just check the pdb (attached) and there was no gap.
>
> Are the coordinates different in the input pdb file and the output rst7
> or pdb file? You may need to add a "set default nocenter on" command to
> avoid a recentering of coordinates by tleap. But at most tleap would
> provide a overall translation, and would not create a "gap".
>
> >
> > The box dimension is stored in present.prmtop.
>
> The coordinates in the prmtop file are generally ignored. As I
> indicated in the previous email, you should look at the final line of
> the $NAMEd.inpcrd file you are creating. That should be the same as
> what you requested.
>
> ....dac
>
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Sep 04 2018 - 12:00:02 PDT