Hi everyone, regarding the parameters for TIP3P water, the file in
amber16/dat/leap/parm/frcmod.tip3p
specifies a HW-HW distance of 1.5136 angstroms,
while Gromacs and Charmm parameter files the same distance is 1.5139.
Is there a reason for this difference?
Regards.
David.