Re: [AMBER] MM-GBSA for recptor-magnesium-ligand complex

From: Urszula Uciechowska <urszula.uciechowska.biotech.ug.edu.pl>
Date: Wed, 13 Jun 2018 15:07:36 +0200

Hi

I checked the sander complex file and mmpbsa complains about the atom
mismatch, I do not really understand why there is an atom mismatch? How
to check where this mismatch is and correct it? I am quite sure that the
topology and crd files are correct? Could the magnesium ion cause the
error?

INFO: Old style inpcrd file read


  FATAL: NATOM mismatch in coord and topology files

Thank you in advance for any suggestions

best
Urszula

> On Thu, Jun 07, 2018, Urszula Uciechowska wrote:
>>
>> CalcError: /users/work/czarek/amber16/bin/sander failed with prmtop
>> complex.top!
>> Error occured on rank 0.
>> Exiting. All files have been retained.
>
> You need to look at the sander output file(s) to get a better idea of
> what the problem is. It will be in the run that used the complex
> trajectory.
>
> ...good luck....dac
>
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>
>



--------------------------------------------
Urszula Uciechowska PhD
University of Gdansk and Medical Univesity of Gdansk
Department of Molecular and Cellular Biology
ul. Abrahama 58
80-307 Gdańsk
Poland


-----------------------------------------
Ta wiadomość została wysłana z serwera Uniwersytetu Gdańskiego
http://www.ug.edu.pl/


_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Jun 13 2018 - 06:30:03 PDT