Re: [AMBER] Ion dissociation computed by umbrella sampling

From: David A Case <david.case.rutgers.edu>
Date: Mon, 12 Feb 2018 07:30:17 -0500

On Thu, Feb 08, 2018, Veronika Jurásková wrote:
>
> I have a question concerning QM/MM umbrella sampling. I would like to
> simulate ion dissociation in a system made of small organic molecule and
> anion in organic solvent. In the system I assume weak interaction between 
> anion and molecule. I chose axis y as a reaction coordinate for the
> dissociation. In the simulation, I use harmonic distance restraint between
> the anion and COM of two atoms in molecule. Problem is, that during the
> simulation, the anion is moving not only in the y direction but also 
> perpendicularly to the plane of molecule. Is this behavior correct when I am
> interested in the dissociation curve?

Yes: this is the "correct" behavior, at least if "correct" means corresponding
to the underlying physical behavior. In reality, the ion and molecule can
interact in many geometries, not just along a single line.

....good luck....dac


_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Mon Feb 12 2018 - 05:00:02 PST