Hi,
The Amber trajectory file is depending upon the nstlim and ntwx. In your case nstlim = 25,000,000 and ntwx = 10,000 so definitely you will get 2500 frames. But you mentioned you got only 250 frames, i can't believe this. Meantime your ntpr = 1000, so will get 25000 mdout files. How many out files you got from the simulation?, My suggestion is if you are reducing the ntpr = 500 and ntwx = 500 you will get 50,000 out files and 50,000 frames.
with regards,
R. A. Jeyaram
________________________________________
From: Paul Meister <meisterp.uwindsor.ca>
Sent: Wednesday, January 17, 2018 1:28 AM
To: AMBER Mailing List
Subject: [AMBER] MD run saving only 250 frames
Hello AMBER users,
I am having an issue with trying to run a 50 ns simulation on an enzyme. We
have recently started using AMBER16 from AMBER14 and have copied over the
production .in files we used for that version. I have attached the md.in
file and md.bash file for reference. I have tried running the input command
separately as well as with the bash script and also as .crd output format.
The input command was:
pmemd.cuda -O -i md.in -o md.out -p md.top -c md.incrd -r md.rst -x md.nc
-ref md.firstcrd -inf md.mdinfo
After I try to load the nc file with VMD or use cpptraj, there are always
only 250 frames in the md.nc file. Is there something I am missing in the
.in file preventing me from saving more than 250 frames?
Thank you for your suggestions,
Paul
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Jan 16 2018 - 23:30:02 PST