[AMBER] the meaning of NONBON in frcmod

From: Zhenyu Meng <fdmm1989.gmail.com>
Date: Wed, 29 Jun 2016 12:26:18 +0800

Dear Amber users,
I wonder what's the meaning of values in NONBON section of frcmod, e.g.
NONBON
  Pt 0.0000 0.0000 ATTN, need revision
I check the website and the two values may be type RE(van der Waals radius
and the potential well depth parameters) or AC(The 6-12 potential
coefficients), so how could I know which type these two values stand for?
Your kind help will be highly appreciated!

-- 
Sincerely,
Mr. Meng Zhenyu
Division of Chemistry and Biological Chemistry
School of Physical and Mathematical Sciences
Nanyang Technological University
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Jun 28 2016 - 21:30:02 PDT