Re: [AMBER] Value of ntrx=7

From: Jason Swails <jason.swails.gmail.com>
Date: Mon, 1 Feb 2016 14:55:43 -0500

On Mon, Feb 1, 2016 at 2:50 PM, Krantzman, Kristin D <KrantzmanK.cofc.edu>
wrote:

> Dear AMBER Community,
> When restarting a trajectory, do we need to use ntrx=7 to read the box
> information from the inpcrd file?
>

​The variable is ntx. The value "7" is the same as "5", although 5 is the
only one documented in the Amber manual, IIRC. And this is not for reading
the box information, it's specifying whether or not velocities are present
in the inpcrd file. If velocities are present, you should use ntx=5 (or
7). If they are not present (e.g., following a minimization), set ntx=1.
The box information will always be looked for if it's needed (and found if
it's present).

HTH,
Jason

-- 
Jason M. Swails
BioMaPS,
Rutgers University
Postdoctoral Researcher
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Mon Feb 01 2016 - 12:00:07 PST