I am confused. The manual states, on p. 310, that ntb=1 is constant
volume. On p.307, the ntp command, when it has a value other than ntp=0,
makes constant pressure. In the performance listing, on
http://ambermd.org/gpus/ for explicit solvent PME, it says it uses
NTB=1, NTP=1. This would lead me to believe constant pressure, constant
volume (and ntt=3 makes constant temperature).
On 11/18/15 9:11 AM, David A Case wrote:
> On Tue, Nov 17, 2015, Robert Molt wrote:
>
>> , an estimate of the maximum system size is given for GPU types. For the
>> conditions for explicit solvent, it lists NTB=1 (which is constant
>> volume) and NTP=1 (which is constant pressure) and NTT=3 (which is the
>> canonical ensemble). I do not know of a PVT ensemble, so either I am
>> very confused on thermodynamics or there is a typo?
> I don't see the problem, but maybe it could be worded more clearly. What in
> the above description makes you think we are talking about a "PVT" ensemble,
> which I agree does not make sense?
>
> For historical reasons that we are reluctant to change, in Amber constant
> volume is given by ntb=1, ntp=0; to move to constant pressure, you have to
> change two variables, going to ntb=2, ntp=1. Other combinations are not
> allowed. The ntt variable is used to distinguish between constant energy and
> constant temperature simulations.
>
> ....hope this helps....dac
>
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
--
Dr. Robert Molt Jr.
r.molt.chemical.physics.gmail.com
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Nov 18 2015 - 07:30:05 PST