[AMBER] Why is water box getting bigger?

From: Karolina Markowska <markowska.kar.gmail.com>
Date: Mon, 19 Oct 2015 13:57:20 +0200

Hello, Amber Users!

I have a problem with my system. It's a small globular protein (286 aa).
When I was doing short simulations (10 ns) there was no problem, but right
now, when I want to do 50 ns simulations (5 x 10 ns) I see there is
something wrong with the system.
The volume is getting smaller, density is increasing and the total energy
is decreasing very fast. I'm using iwrap, so I grep some informations about
the water box size, and this is my output:

first 10 lines:
wrapping first mol.: -72.25756 0.00000 0.00000
wrapping first mol.: -72.25756 0.00000 0.00000
wrapping first mol.: -72.32379 0.00000 0.00000
wrapping first mol.: -72.32379 0.00000 0.00000
wrapping first mol.: -72.27254 0.00000 0.00000
wrapping first mol.: -72.27254 0.00000 0.00000
wrapping first mol.: -72.29022 0.00000 0.00000
wrapping first mol.: -72.29022 0.00000 0.00000
wrapping first mol.: -72.26856 0.00000 0.00000
wrapping first mol.: -72.26856 0.00000 0.00000

last 10 lines:
wrapping first mol.: -192.79918 -68.16483 -472.25958
wrapping first mol.: -192.79918 -68.16483 -472.25958
wrapping first mol.: -192.78991 -68.16155 -472.23687
wrapping first mol.: -192.78991 -68.16155 -472.23687
wrapping first mol.: -192.76965 -68.15439 -472.18724
wrapping first mol.: -192.76965 -68.15439 -472.18724
wrapping first mol.: -192.78179 -68.15868 -472.21697
wrapping first mol.: -192.78179 -68.15868 -472.21697
wrapping first mol.: -192.81269 -68.16961 -472.29267
wrapping first mol.: -192.81269 -68.16961 -472.29267

For the file preparation I'm using this procedure:

source leaprc.ff14SB
loadAmberParams frcmod.ionsjc_tip3p
solute = loadpdb protein.pdb
solvent = loadpdb wat.pdb
complex = combine {solute solvent}
solvateoct complex TIP3PBOX 10
addions complex Na+ 0
savepdb complex protien_complex.pdb
saveamberparm complex protein_complex.prmtop protein_complex.inpcrd
quit

And here is the production script:

# 5 ns production Langevin dynamics
 &cntrl
   imin=0,
   irest=1, ntx=5,
   ntpr=500, ntwx=500, ntwr=500,
   ntb=2, cut=10, nsnb=10, iwrap=1,
   nstlim=5000000, nscm=0, dt=0.002,
   ntt=1, temp0=300, tempi=300, ig=-1,
   ntp=1,
   ntc=2, ntf=2,
 /

What could be the problem here?
I was doing simulations using the same scripts, but with bigger molecules,
and there was no such problem. Please, help!

Best regards,
Karolina Markowska
PhD student
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Mon Oct 19 2015 - 05:00:03 PDT