Re: [AMBER] PMEMD: Warning: ieee_inexact is signaling

From: Khabiri, Morteza <khabiri.med.umich.edu>
Date: Mon, 3 Aug 2015 19:40:14 +0000

I am doing thermodynamic integration. As far as I know I have to play with ntf and ntc. when I put ntf=1 and ntc = 1, the system runing without error and any out put. mdout is empty.
my input file is as follow:
TI simulation
 &cntrl
   imin = 0, nstlim = 100000, irest = 1, ntx = 5, dt = 0.002,
   ntt = 3, temp0 = 298.0, gamma_ln = 5.0, ig = -1,
   ntc = 1, ntf = 1, ntb = 1,ntp = 0,
   ioutfm = 1, iwrap = 1,
   ntwe = 1000, ntwx = 10000, ntpr = 10000, ntwr = 20000,


   icfe = 1, ifsc = 1, clambda = 0, scalpha = 0.5, scbeta = 12.0,
   logdvdl = 1,
   ifmbar = 1, bar_intervall = 1000, bar_l_min = 0.0, bar_l_max = 1.0,
     bar_l_incr = 0.1,
   timask1 = ':116,149', timask2 = ':159,160',
   scmask1 = ':116,149', scmask2 = ':159,160',


 &end



thanks




________________________________
From: Khabiri, Morteza
Sent: Monday, August 03, 2015 9:21 AM
To: amber.ambermd.org
Subject: PMEMD: Warning: ieee_inexact is signaling

Dear amber users,
I am trying to calculate TI in amber cpu version. I have a problem with the following error:

PMEMD Terminated Abnormally!
Warning: ieee_inexact is signaling

I was using exactly the same system with the same input from "http://ambermd.org/tutorials/advanced/tutorial9/#remarks" toturial but I have got the same error. I would be happy if you can help me.

Thanks

Morteza
**********************************************************
Electronic Mail is not secure, may not be read every day, and should not be used for urgent or sensitive issues
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Mon Aug 03 2015 - 13:00:04 PDT