Re: [AMBER] adQM/MM vlimit exceeded problem

From: Andreas Goetz <agoetz.sdsc.edu>
Date: Mon, 24 Nov 2014 13:44:25 -0800

Hi Aixiao,

You seem to be using SHAKE which does not make sense. You have to switch SHAKE off in the QM region in order to allow proton transfer. This means you have to use a flexible water model and run without SHAKE.

If you send me your input files, I can probably tell you more.

All the best,
Andy
--
Dr. Andreas W. Goetz
Assistant Project Scientist
San Diego Supercomputer Center
Tel  : +1-858-822-4771
Email: agoetz.sdsc.edu
Web  : www.awgoetz.de
On Nov 23, 2014, at 9:30 PM, Andreas Goetz wrote:
> Dear Aixiao,
> 
> Your general simulation setup sounds reasonable (if your QM method is able to describe proton transfer well). The problems you see might be related to a bug in the released version of the adQM/MM implementation. Could you please send me your input files off-list so I can check what is going on? Thanks.
> 
> All the best,
> Andy
> --
> Dr. Andreas W. Goetz
> Assistant Project Scientist
> San Diego Supercomputer Center
> Tel  : +1-858-822-4771
> Email: agoetz.sdsc.edu
> Web  : www.awgoetz.de
> 
> On Nov 20, 2014, at 2:32 AM, Aixiao Li wrote:
> 
>> Hi,
>> I am working on a system that bulk solvent participates directly in a proton transfer reaction. So the adaptive solvent QM/MM is a perfect solution. My goal is to run umbrella sampling with adQM/MM and do potential of mean force (PMF) study.
>> 
>> So basically the whole story is adQM/MM umbrella sampling with nmr constraints on "O" (from my reactant) and "H" (from one bulk water) distance, let us say, windows from 2.0 ang to 1.0 ang.
>> 
>> But while running simulations, as I define my reactant+7H2Os as my A region (with one H2O as my proton donor candidate) and 5 waters in the T region, the simulation behaves well for several time steps, but sometimes it appears 
>> "vlimit exceeded for step..." and the calculations keep going on. And the calculation could stop with error message like:
>> 
>>                      "Coordinate resetting (SHAKE) cannot be accomplished,
>>                           deviation is too large
>>                     NITER, NIT, LL, I and J are :      0      4     20     80     78
>> 
>>                     Note: This is usually a symptom of some deeper
>>                     problem with the energetics of the system.
>> 
>> Is this because that my T region is not big enough or too big? I checked the configuration with VMD, and I could not find out anything strange, there is no hydroxide or hydronium ions formed...
>> 
>> thank you very much
>> 
>> 
>> best 
>> 
>> _______________________________________________
>> AMBER mailing list
>> AMBER.ambermd.org
>> http://lists.ambermd.org/mailman/listinfo/amber
> 
> 
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Mon Nov 24 2014 - 14:00:04 PST