Yes it is there but it is:
1) Only for waters
2) Uses a hard cutoff at the QM/MM boundary - I.e. as a water leaves and a
new water enters there is no accounting for this not being a smooth
transition. This leads to discontinuities in the potential and hence
instability unless a very tight thermostat is used. The best option is to
use a proper transition region based adaptive approach that gives smooth
potentials as a water molecule transitions from QM to MM.
See: http://www.rosswalker.co.uk/papers/ct300331f.pdf
as well as
JCTC 2009, 5, 2212
And the AMBER adaptive QM/MM paper that should have been written by now
(hint hint - names with-held to protect the guilty).
All the best
Ross
On 7/30/13 8:30 PM, "Jason Swails" <jason.swails.gmail.com> wrote:
>On Tue, Jul 30, 2013 at 11:22 PM, Ross Walker <ross.rosswalker.co.uk>
>wrote:
>
>>
>> FYI - Adaptive QM/MM support will be part of the next version of AMBER.
>>It
>> would have been available earlier but unfortunately NSF ran out of money
>> before they could fund our proposal for developing the method further.
>>
>
>But "variable solvent" is there, right? It appears to have a test case in
>Amber 12, and I couldn't find any reason why the code would trap it...
>
>If all you need to do is swap solvent, you may be able to get away with
>vsolv=1, but I'll defer to the experts on this one.
>
>HTH,
>Jason
>
>--
>Jason M. Swails
>BioMaPS,
>Rutgers University
>Postdoctoral Researcher
>_______________________________________________
>AMBER mailing list
>AMBER.ambermd.org
>http://lists.ambermd.org/mailman/listinfo/amber
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Jul 30 2013 - 21:00:05 PDT