Re: [AMBER] Creating a new Solvatebox

From: Chinthaka Ratnaweera <cnr88.msstate.edu>
Date: Tue, 23 Jul 2013 14:19:01 -0500

I followed the procedure in tutorial 15.

This is my packmol input file

tolerance 2.0
output ethbox.pdb
filetype pdb
structure ethanol.pdb
number 1000 # Number of molecules
inside cube 0. 0. 0. 50. # x, y, z coordinates of box, and length of box in
Angstroms
end structure

Then use leap to generate initial coordinates and topologies.
source leaprc.gaff
ETH = loadmol2 ethanol.mol2
ETHBOX = loadpdb ethbox.pdb
setbox ETHBOX centers
saveAmberParm ETHBOX ethbox.prmtop ethbox.inpcrd

But when running minimization under NVT it gave me this error
forrtl: severe (174): SIGSEGV, segmentation fault occurred

my minimization input is
test run 1
 &cntrl
     imin = 1, ntpr = 100, ntwx=100, maxcyc = 10000, ntb=1
&end

This starts the first step of minimization
 TESTING RELATIVE ERROR over r ranging from 0.0 to cutoff
| CHECK switch(x): max rel err = 0.2738E-14 at 2.422500
| CHECK d/dx switch(x): max rel err = 0.8314E-11 at 2.736960
 ---------------------------------------------------
| Local SIZE OF NONBOND LIST = 1264139
| TOTAL SIZE OF NONBOND LIST = 1264139


   NSTEP ENERGY RMS GMAX NAME NUMBER
      1 2.1423E+09 4.7538E+08 4.7855E+10 H4 2698

 BOND = 547891.8779 ANGLE = 201752.1037 DIHED =
2455.8141
 VDWAALS = ************* EEL = 12317.8836 HBOND =
0.0000
 1-4 VDW = 72044523.0714 1-4 EEL = -22796.8084 RESTRAINT =
0.0000


Is this because of my box size?


On Tue, Jul 23, 2013 at 10:02 AM, David A. Case <case.biomaps.rutgers.edu>wrote:

> On Mon, Jul 22, 2013, Chinthaka Ratnaweera wrote:
> >
> > Once the saveoff command make a box 'unit' ( I guess I have to save it
> as
> > a lib file), inorder to use that unit to solvate the protein, do I have
> to
> > use loadoff command to open it and give this unit name as second argument
> > in solvatebox command?
>
> Yes.
>
> >
> > Does size of the solvate box matters when setup the initial box using
> > packmol?
>
> It's not a big deal which size you choose. Most of the "standard" boxes
> are really smaller than they should be (some were made back in the 1980s
> when
> computers were much slower.) The solvateBox and solvateOct routines will
> replicate and truncate boxes as needed. Something on the order of 1000
> ethanol molecules should be fine.
>
> ...good luck....dac
>
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>



-- 
Chinthaka Nadun Ratnaweera
Hand Lab Rm 1126
Mississippi State University
310 Presidents Circle
Starkville, MS 39762
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Jul 23 2013 - 12:30:02 PDT