Re: [AMBER] Problem to run sander with more than 60 atom types

From: Jason Swails <jason.swails.gmail.com>
Date: Thu, 28 Feb 2013 10:14:17 -0500

On Thu, Feb 28, 2013 at 9:24 AM, Elise Duboué-Dijon <
elise.duboue-dijon.ens.fr> wrote:

> Dear Jason,
>
> Following your advices, we changed the amber12 code to be able to run it
> with systems that have more than 60 atom types.
>

How many atom types do you have _exactly_? The changes you made below
correspond to just 100 atom types...

Also, can you use pmemd instead of sander? pmemd does not suffer from this
limitation. (As a note, I implemented the changes in the RCW: WARNING
comment block at the top of parms.F90 for the upcoming Amber version).

Can you re-compile with the "-g" flag to add debug symbols? (You should be
able to configure with the -debug flag), and re-run. Hopefully that will
provide a backtrace so we know where the segfault is occurring.

Thanks,
Jason

-- 
Jason M. Swails
Quantum Theory Project,
University of Florida
Ph.D. Candidate
352-392-4032
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Thu Feb 28 2013 - 07:30:03 PST