[AMBER] sander pb focusing error

From: Niel Henriksen <niel.henriksen.utah.edu>
Date: Thu, 13 Oct 2011 21:17:06 -0600

Hi,

A while ago the following error was reported for pb calculations
performed by a nab program:

pb_fdfrc(): Atom out of focusing box

see the post here http://archive.ambermd.org/201103/0189.html

The symptoms include that if the "problem" frame is used in isolation,
the error does not occur, but when part of a trajectory the error
occurs.

I'm having the same problem, except in sander. When I use the
mmpbsa_py_energy program, I have no problem. When I use
sander I get the focusing error. I notice that mmpbsa_py_energy
produces Reaction Field Energy values every step, while sander does
not. Maybe the grid is not being recalculated?

The files to reproduce the problem are here:
http://www.amber.utah.edu/biodata/sander-pbsa-problem/

sander produces the error with frames_1-3.traj but not frames_2-3.traj.
mmpbsa_py_energy works with both. (Fully patched Amber 11, AT 1.5)

Thanks for any help,
--Niel