I have been running some MM-PBSA calculations with a Nab program designed to
perform the PB calculations. I have come across an error when running these
calculations. When I run the program, an error occurs during frame 82 that
is printed out to the screen:
Cavity solvation energy 90.1798
61 91 127
pb_fdfrc(): Atom out of focusing box 61 91 127
This is reproducible when I re-run the same calculation. It always stops on
this particular frame. However, when I run the exact same calculation on
only frame 82, this error does not occur. I was curious if anyone else has
come across this issue with nab? I assume this is a problem with how the
code is written (specifically with regards to focusing) since the exact same
calculation works for one frame, but dies when many frames are ran before
it.
I look forward to your response.
Thanks,
Bill
--
Bill Miller III
Quantum Theory Project,
University of Florida
Ph.D. Graduate Student
352-392-6715
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Mar 09 2011 - 12:30:03 PST