Re: [AMBER] Large pressure fluctuations over the whole run

From: case <case.biomaps.rutgers.edu>
Date: Mon, 26 Sep 2011 22:19:59 -0400

On Mon, Sep 26, 2011, Adrian Roitberg wrote:

> Well, for starters, did you change the compressibility value when you
> run your simulations ? The default value in amber is for water, so you
> need to change it in the input.

The compressibility value in sander/pmemd only affects the rate at which the
system comes to equilibrium; the magnitude of the pressure fluctations should
be independent of this choice. Given that the value to taup is pretty
arbitrary anyway (assuming is is large enough, say >= 1 ps), changing it for
different liquids is rather a matter of taste.

>
> In any case, all solids and most liquids are incompressible as a general
> rule.

incompressible -> nearly incompressible

>>> We found that at the first run (of 500 ps) the average pressure lead to a
>>> high value. In the following runs this value rise fluctuating between 0.6 -
>>> 1.7 (the average) this value don't reach 1 even after 50 ns of running.

This is expected; see, e.g. http://ambermd.org/Questions/pressure.html

...dac