On Fri, Dec 17, 2010, Bongkeun Kim wrote:
>
> I just run the hybrid remd and checked the output file.
> It said ********** on EPot. Does it mean only the number is too big to
> print or is there any problem on this run?
There seems to be a problem with the restraint energy:
> EELEC = -6589.2279 EGB = -3004.6220 RESTRAINT =57092146.9150
You can't run replica exchange simulations with ntr>0 (unless, I guess, that
all replicas have the same reference structure. Also, be sure that you can
sucessfully run non-exchange simulations at each temperature of interest.
....dac
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Fri Dec 17 2010 - 06:30:06 PST