I wouldn't expect it, but are you seeing something?
Also, I'll get to the IWRAP issue sometime later today. I suspect the fix is but a few lines of code but I'm neckdeep in multi-GPU code right now. And in that case, the more independent bandwidth between GPUs the better...
-----Original Message-----
From: amber-bounces.ambermd.org [mailto:amber-bounces.ambermd.org] On Behalf Of Sasha Buzko
Sent: Monday, June 07, 2010 09:24
To: AMBER Mailing List
Subject: [AMBER] amber.cuda performance on Nvidia S2050?
Hi all,
has anyone had any experience with amber.cuda using Nvidia S2050
rack-mounted units? I wonder if there is any loss in performance due to
each pair of Tesla cards sharing a PCI-E slot on the motherboard.
It didn't seem to be a problem with the previous generation cards, but
with faster Fermi cards the bottleneck could possibly shift to the
interface. Has anyone seen such a drop in individual performance when
all cards in S2050 execute at the same time?
Thanks for any info
Sasha
Ross Walker wrote:
> Hi Dean,
>
>
>> I have a quick question:
>>
>> I'm just curious as to the theoretical explanation for why the box
>> clearance
>> should be greater than your cutoff?
>>
>
> The requirement, due to the fact that AMBER implements the minimum image
> convention within the code. In that it does not have image atoms and expects
> each atom to only interact with itself once in the direct space calculation
> means that the minimum box dimension must be at least the cutoff size.
>
>
>> If I did 10A clearance for my protein in a water box, and used 10A for
>> my cutoff, what would be the deleterious results?
>>
>
> In this case your box is almost certainly large enough even allowing for the
> density increasing during NPT runs. The solvatebox command in leap adds
> sufficient water so that no single solute atom is within the buffer distance
> of the box edge. In your case if your protein was 10 angstroms by 10
> angstroms by 10 angstroms (pretty small!) then you would have added a
> minimum of 10 angstroms of water on each side of your solute. This gives you
> a box with a minimum size of 30 angstroms^3. This is 3 times larger than the
> minimum size implied by the minimum image convention with a 10 angstrom
> cutoff so you have significant room to spare.
>
> Note, the code continually checks that the minimum image convention is not
> violated and will quit it your box becomes too small rather than running and
> generating incorrect answers.
>
> I hope this helps.
>
> All the best
> Ross
>
> /\
> \/
> |\oss Walker
>
> | Assistant Research Professor |
> | San Diego Supercomputer Center |
> | Tel: +1 858 822 0854 | EMail:- ross.rosswalker.co.uk |
> | http://www.rosswalker.co.uk | http://www.wmd-lab.org/ |
>
> Note: Electronic Mail is not secure, has no guarantee of delivery, may not
> be read every day, and should not be used for urgent or sensitive issues.
>
>
>
>
>
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>
>
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
-----------------------------------------------------------------------------------
This email message is for the sole use of the intended recipient(s) and may contain
confidential information. Any unauthorized review, use, disclosure or distribution
is prohibited. If you are not the intended recipient, please contact the sender by
reply email and destroy all copies of the original message.
-----------------------------------------------------------------------------------
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Mon Jun 07 2010 - 11:00:04 PDT