it's possible that the restraint force constant is too high, or
perhaps you have problems with the force field parameters for the
ligand (if you have one).
it's very hard to say from the current info. I think you need to
carefully analyze the output file. what is the pressure? what about
temperature? are these both the values that you requested? it seems to
be having problems equilibrating, but the bubble is probably a symptom
and you need to analyze the output to find the initial problem.
On Sat, May 8, 2010 at 6:55 AM, mish <smncbr.gmail.com> wrote:
> Hi,
> I tried 100ps equilibration at strong pressure coupling ( at taup = 0.1) but
> still getting those patterns and density is less than 1 after the equil.
> What could be other possible reason behind this patter like vacuum bubbles
> ?
> reg
> ...mish
>
> On Fri, May 7, 2010 at 12:43 PM, Carlos Simmerling <
> carlos.simmerling.gmail.com> wrote:
>
>> it looks to me like the pressure might not be equilibrated and the
>> density is low. the patterns look like vacuum bubbles.
>> try to do your water equilibration step with a strong pressure coupling
>> (0.1).
>>
>>
>>
>> On Fri, May 7, 2010 at 12:59 AM, mish <smncbr.gmail.com> wrote:
>> > Hello Dr Simmerling
>> > There is prmtop and mrcrd of from the last snapshot from step3. u can
>> have a
>> > look in vmd because from a sinle pic u might not see the problem in all
>> > planes. Step 3 final density is slightly less than 1.
>> > scripts for ptraj i used is -
>> > -----------------ptraj.in----------------
>> > trajin step3.rst
>> > center :1-266 mass origin
>> > image center familiar com :1-266
>> > trajout step6last_img.rst
>> > ----------------------------------------------
>> > Thanking u ..
>> > ...mish
>> > On Thu, May 6, 2010 at 6:31 PM, Carlos Simmerling
>> > <carlos.simmerling.gmail.com> wrote:
>> >>
>> >> step 3 seems ok- maybe a picture would help us understand what you see.
>> >> make sure the ptraj imagine is done correctly. is the step 3 final
>> >> density ok? the pressure coupling is pretty weak.
>> >>
>> >>
>> >> On Thu, May 6, 2010 at 8:56 AM, mish <smncbr.gmail.com> wrote:
>> >> > Hi,
>> >> > Fixed means restrained. but used very tight restrain
>> >> > (restraint_wt=200.0).
>> >> > I used proper ensembles mentioned in literature. But I am copying
>> >> > detail of
>> >> > input file so that u can point out other mistakes too..
>> >> >
>> >> > ------------ -------Step 1 ---------------------------
>> >> > minimization of solvent molecules
>> >> > &cntrl
>> >> > imin=1,maxcyc=3000,ncyc=500,
>> >> > cut=10.0,ntb=1,
>> >> > ntc=1,ntf=1,
>> >> > ntpr=50,
>> >> > ntr=1, restraintmask=':1-266',
>> >> > restraint_wt=200.0,
>> >> > /
>> >> >
>> >> > ------------------- step 2 --------------------------
>> >> > heating system with fixed protein
>> >> > &cntrl
>> >> > imin=0,irest=0,ntx=1,
>> >> > nstlim=300000,dt=0.001,
>> >> > ntc=2,ntf=2,
>> >> > cut=10.0, ntb=1,
>> >> > ntpr=1000, ntwx=1000,
>> >> > ntt=3, gamma_ln=2.0,
>> >> > tempi=10.0, temp0=300,
>> >> > ntr=1, restraintmask=':1-266',
>> >> > restraint_wt=200.0,
>> >> > nmropt=1
>> >> > /
>> >> > &wt TYPE='TEMP0', istep1=0, istep2=250000,
>> >> > value1=10.1, value2=300, /
>> >> > &wt TYPE='END' /
>> >> >
>> >> > ------------------- step 3 --------------------------equilibrating
>> water
>> >> > in
>> >> > the system with fixed protein
>> >> > &cntrl
>> >> > imin=0,irest=1,ntx=5,
>> >> > nstlim=700000,dt=0.001,
>> >> > ntc=2,ntf=2,
>> >> > cut=10.0, ntb=2, ntp=1, taup=5.0,
>> >> > ntpr=1000, ntwx=1000,
>> >> > ntt=3, gamma_ln=2.0,
>> >> > temp0=300,
>> >> > ntr=1, restraintmask=':1-266',
>> >> > restraint_wt=200.0,
>> >> > /
>> >> >
>> >> >
>> >> > and i can see that weired behavior after step 3, which i supposed to
>> be
>> >> > proper equilibrated octahedral box after 70 ps equilibration.
>> >> >
>> >> > ....mish
>> >> >
>> >> >
>> >> > On Thu, May 6, 2010 at 2:28 PM, Carlos Simmerling <
>> >> > carlos.simmerling.gmail.com> wrote:
>> >> >
>> >> >> you don't say the most important thing- did you use NVT or NPT in
>> each
>> >> >> step? and when you say "fixed", do you mean frozen or restrained?
>> >> >>
>> >> >> On Thu, May 6, 2010 at 8:00 AM, mish <smncbr.gmail.com> wrote:
>> >> >> > Hi all :
>> >> >> >
>> >> >> > I am trying to do some MM-PB/SA calculation in my system. For
>> >> >> equilibration
>> >> >> > of the salivated system (octahedral TIP3P) i used the fallowing
>> >> >> > scheme-
>> >> >> > 1- Minimization of solvent molecules with fixed protein
>> >> >> > 2- Heating system with fixed protein (300 ps)
>> >> >> > 3- Equilibrating water in the system with fixed protein (700 ps)
>> >> >> > 4- Minimization of protein with with fixed water
>> >> >> > 5- Heating system with fixed water (300ps)
>> >> >> > 6- Equilibration of whole system without any restrain (10 ns)
>> >> >> >
>> >> >> > I found that the density in the step 6 is less than 1 for first
>> few
>> >> >> > few
>> >> >> ps
>> >> >> > and then it adjust is very soon. When i look in adjustment of water
>> >> >> molecule
>> >> >> > after each step, I found a weird thing after step 3. I did imaging
>> >> >> > with
>> >> >> > ptraj and found that few planes of octahedral water-box have small
>> >> >> > well
>> >> >> > shaped arrangenemt of water. I am really surprised that why this
>> >> >> happened.
>> >> >> > Is it may be due to only 12A layer of water box, that PBC is
>> showing
>> >> >> effcet
>> >> >> > of adgacent protein ?
>> >> >> >
>> >> >> > Reigards
>> >> >> >
>> >> >> > ..mish
>> >> >> > _______________________________________________
>> >> >> > AMBER mailing list
>> >> >> > AMBER.ambermd.org
>> >> >> > http://lists.ambermd.org/mailman/listinfo/amber
>> >> >> >
>> >> >>
>> >> >> _______________________________________________
>> >> >> AMBER mailing list
>> >> >> AMBER.ambermd.org
>> >> >> http://lists.ambermd.org/mailman/listinfo/amber
>> >> >>
>> >> > _______________________________________________
>> >> > AMBER mailing list
>> >> > AMBER.ambermd.org
>> >> > http://lists.ambermd.org/mailman/listinfo/amber
>> >> >
>> >>
>> >> _______________________________________________
>> >> AMBER mailing list
>> >> AMBER.ambermd.org
>> >> http://lists.ambermd.org/mailman/listinfo/amber
>> >
>> >
>>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Sat May 08 2010 - 04:30:03 PDT